• <pre id="HEMiqQ"></pre>

          1. <legend id="HEMiqQ"><tr id="HEMiqQ"></tr></legend>

                  IP5X IP6X Sand and dust proof test chamber BND-IP56X

                  Product Description:Name:IP5X IP6X Sand and dust proof test chamberType:BND-IP56XTesting Standard:In accordance with IEC60529: 2001 "Degrees of protection provided by enclosures (IP Code)", GB4208-2008 "Shell protection class (IP code)" 13.4,13.5 terms and Figure 3 and GB7000.1 "Lamps Part I: General requirements and tests" 9.2.1, 9.2.2 and the requirements of Figure 6.
                  Description

                  Product Description:

                  Name:IP5X IP6X Sand and dust proof test chamber

                  Type:BND-IP56X


                  Testing Standard:

                  In accordance with IEC60529: 2001 "Degrees of protection provided by enclosures (IP Code)", GB4208-2008 "Shell protection class (IP code)" 13.4,13.5 terms and Figure 3 and GB7000.1 "Lamps Part I: General requirements and tests" 9.2.1, 9.2.2 and the requirements of Figure 6.


                  Usage:

                  The test box for low-voltage electrical appliances, electrical appliances, instruments, meters lamps, household appliances and other products in the storage, transportation and use of sand and dust are often affected by the environment. Especially cars, electrical appliances by the impact of dust is more significant. This equipment is used artificial dust environment, to test the test of dust resistance of the test equipment, test specimens in this environment in the sealing and corrosion resistance


                  Model

                  BND-IP56X -125L

                  BND-IP56X -500L

                  BND-IP56X -1000L

                  BND-IP56X -1500LA

                  BND-IP56X -1500LB

                  BND-IP56X -1500LS

                  Internal dimension

                  (Length*Depth*Height) mm

                  500*500* 500

                  800*800* 800

                  1000*1000* 1000

                  1000*1000* 1500

                  1000*1500* 1000

                  1500*1000* 1000

                  External dimension (L*D*H) mm

                  L950×D720×H1500

                  L1250×D1020×H1770

                  L1450×D1220×H1970

                  L1450*D1220*H1970

                  L1450*D1720*H1970

                  L2050*D1220*H1970

                  Testing Temp

                  RT+10~70℃(should be declare when order)

                  Humidity.Range

                  45%~75%(can’t display)

                  Mess diameter

                  50um

                  Wire spacing

                  75um

                  talc powder quantity

                  2~4kg/m

                  type of testing dust

                  dry talc powder

                  falling dust

                  Free fall

                  Testing time

                  0-999 H (adjust)

                  time of vibration

                  0-999H(adjust)

                  timing accuracy

                  ±1 s

                  External material

                  A3 steel with powder coating

                  Internal material

                  SUS304stainless steel plate

                  gate structure

                  the door with a big window, and equipped with dust scraper

                  protective device

                  0-999/H(Adjust)

                  vacuum degree

                  0—10Kpa(Adjust)

                  speed of evacuation

                  0-2400L/H(Adjust)

                  0-4800 L/H(Adjust)

                  0-6000 L/H(Adjust))

                  0-6000 L/H(Adjust))

                  Power supply(V)

                  AC220V

                  380V

                  Power(KW)

                  1KW

                  1.5KW

                  2.0KW

                  3.5kw

                  Standard

                  IEC60529:1989+A1:1999、GB4208、GB7000.(IP5X、IP6X)

                   