                  ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

                  Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
                  Description

                  Product Description:

                  Name:ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

                  Type:ORP10

                  Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.

                  ■ ORP measurement

                  ■ Output Interface with RS485, Voltage, Current

                  ■ High accuracy with excellent stability

                  ■ Reverse power protection and Built-in TVS/ESD protection


                  Specifications


                  Output Interface

                  Analog Voltage 0-2V        

                  (Output resistance ~0ohm)

                  Analog Current 4-20mA        

                  (Load Resistor<500ohm)

                  RS485        

                  Modbus-RTU

                  Power Supply

                  3.9-30V/DC

                  12-30V/DC

                  3.9-30V/DC

                  Power Consumption

                  10mA@24V DC

                  30mA@24V DC        

                  (with 20mA output signal)

                  10mA@24V DC

                  ORP Measurement

                  Range:+/-2000mV,Resolution:1mV,Accuracy:±2%

                  IP Ratings

                  Electrode:IP68        

                  Transmitter:IP65

                  Operating Temperature

                  -40~85℃

                  Installation

                  Electrode:3/4″NPT screw threads        

                  Transmitter:Mounting hole

                  Cable Length

                  Power and Signal Cable:2 meters or Customize        

                  Electrode Cable:5 meters

                  Dimension

                  Electrode:3/4″NPT screw threads        

                  Transmitter:128*70*42mm



                  Parameters

                  Code

                  Comments

                  Code 1:        

                  Product Series

                  ORP10

                  ORP10 transmitter

                  Code 2:        

                  Power Supply

                  A        

                  B

                  3.9-30V DC        

                  3.3-16V

                  Code 3:        

                  ORP Range

                  A        

                  B

                  C

                  +/-2000mV        

                  +/-1000mV

                  Customize

                  Code 4:        

                  Output Interface

                  A        

                  B

                  C

                  D

                  E

                  F

                  G

                  Analog Voltage 0-2V        

                  Analog Current 4-20mA

                  RS485,Modbus-RTU

                  RS485,Modbus-RTU & Analog Voltage 0-2V

                  RS485,Modbus-RTU & Analog Current 4-20mA

                  SDI-12

                  Customize

                  Code 5:        

                  Cable Length

                  002        

                  XXX

                  Electrode Cable:5 meters , Power and Signal Cable:2 meters        

                  Electrode Cable:5 meters , Power and Signal Cable:xxx meters

                  Ordering Code Example:

                  ORP10 transmitter Power Supply 3.9-30V DC, ORP Range +/-2000mV, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ORP10 – A A C 005