                  Product Description:Name:Three box-type Thermal shock Test ChamberType:BND-HLR3Purpose:It is necessary test equipment for the aerospace, automotive, home appliances, research and other fields, used for examination and identification of parameters, performance and the use of adaptive of electrical, electronics, automotive electronics, materials and other products, after making high and low temperature impact test. Applied to schools, factories, military, research, and other organizations
                  Description

                  Product Description:

                  Name:Three box-type Thermal shock Test Chamber

                  Type:BND-HLR3


                  Purpose:

                  It is necessary test equipment for the aerospace, automotive, home appliances, research and other fields, used for examination and identification of parameters, performance and the use of adaptive of electrical, electronics, automotive electronics, materials and other products, after making high and low temperature impact test. Applied to schools, factories, military, research, and other organizations


                  Product Spec.and Technical parameter table

                  model

                  BND-HLR3-80

                  BND-HLR3-100

                  BND-HLR3-150

                  performance

                  Preheat room

                  Upper limit preheat temperature

                  200ºC

                  Heating time

                  ﹢20~﹢200ºC≈20min

                  Precool room

                  Lower limit precool temperature

                  ﹣75ºC

                  Cooling time

                  ﹢20~﹣70ºC≈80min

                  Workroom

                  Temperature shock range

                  (-55ºC~-10)~(50~﹢150ºC)

                  Temperature fluctuation

                  ≤±0.5ºC

                  Temperature deviation

                  ≤±2ºC

                  Temperature revert time

                  ≤5min

                  Temperature revert
                         conditions

                  CJ602S3Ⅰ

                  Condition 1

                  sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                  Condition 2

                  sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                  CJ602S3Ⅱ

                  Condition 1

                  sample load: 20kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                  Condition 2

                  sample load: 20kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                  Condition 3

                  sample load: 7.5kg with  plastic package IC;sample exposed: 30min in ﹢150ºC,30min in ﹣55ºC

                  CJ603S3Ⅰ

                  Condition 1

                  sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                  Condition 2

                  sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                  CJ603S3Ⅱ

                  Condition 1

                  sample load: 20kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                  Condition 2

                  sample load: 20kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                  Condition 3

                  sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢150ºC,30min in ﹣55ºC

                  CJ605S3Ⅰ

                  Condition 1

                  sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                  Condition 2

                  sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                  CJ605S3Ⅱ

                  Condition 1

                  sample load: 20kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                  Condition 2

                  sample load: 20kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                  Condition 3

                  sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,30min in ﹣55ºC

                  construction

                  shell

                  cooling steel plate,surface spray

                  inner

                  steel plate

                  refrigeration

                  insulate

                  Rigid Polyurethane Foam+extra-fine glass-wool

                  mode

                  cascade refrigerating compressor

                  compressor

                  import compressor

                  Cable port(mm)

                  one on left side Φ50

                  Controller

                  color LCD touchscreen display

                  recording equipment

                  temperature recorder(optional)

                  communication Interface

                  RS485 interface,RS232 interface

                  Workroom dimensions(mm)

                  D

                  400

                  400

                  500

                  W

                  500

                  500

                  600

                  H

                  400

                  500

                  500

                  Exterior dimensions(mm)

                  D

                  2500

                  2700

                  2900

                  W

                  1000

                  1000

                  1130

                  H

                  1950

                  2000

                  2100

                  Installed power(KW)

                  35

                  48

                  50

                  46

                  56

                  56

                  Power Supply

                  AC380V 50Hz Three-phase four-wire + protective earth wire

                  Standard Configuration

                  A copy of the instruction and test report for the product, A certificate and quality assurance.2 Shelf and 4 shelves .

                  Standards Applied

                  GJB150.5