                  UL 94 Horizontal and vertical flame test apparatus BND-SPR

                  The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
                  Description

                  Product Description:

                  Name:UL 94 Horizontal and vertical flame test apparatus

                  Type:BND-SPR


                  The Basic introduction of the flame tester:

                  1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

                  2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


                  Technical Parameter of flame test:

                  Model

                  BND-SPR   Horizontal vertical flame tester

                  Kinds

                   500W(5V class )

                   50W(HB/V class)

                  Test Flame

                  500W(burning test for V-0,V-1,V-2  classification)

                  50W(burning test for V-0,V-1,V-2 classification)

                  Burner Tube

                  Internal diameter: Φ 9.5mm±0.3mm

                  Internal diameter: Φ 9.5mm±0.3mm, 

                  Burning Angle

                  0°,20°,45°

                  0°,20°,45°

                  Thermocouple

                  Type K (Ni/Cr - Ni/Al)

                  Type K (Ni/Cr - Ni/Al)

                  Thermocouple Size 

                  0.5 mm

                  0.5 mm

                  Standard Copper Block 

                  9mm±0.01mm,

                  weight:10g±0.05g before drilling.  

                  5.5mm±0.01mm,

                  weight:76g±0.01g before drilling.

                  Time for Temperature to Increase

                  From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

                  From 100°C±5°C to 700°C±3°C;

                  44s±2s (preset)

                  Gas Flow

                  965±32ml/min

                  105±10ml/min

                  Gas Supply

                  methane,min.98% purity

                  methane,min.98% purity

                  water-column 

                  125m±5mm

                  ‹10mm

                  Test  Time

                  54±2s

                  44±2s

                  Flame Height Indicator

                  40±1mm

                  20±1mm

                  Volume Of Chamber

                  >0.5m³, black interior

                  >0.5m³, black interior

                  Conform to standard

                  UL94,IEC60695-11-3,IEC60695-11-20

                  UL94,IEC60695-11-4,IEC60695-11-10