• <pre id="HEMiqQ"></pre>

          1. <legend id="HEMiqQ"><tr id="HEMiqQ"></tr></legend>

                  Walk-in environmental test chamber BND-EK

                  Product Description:Name:Walk-in environmental test chamberType:BND-EKPurpose:Non-standard testing instrument(It is applicatable for the testing of electronics,household appliances, automotive electronics and materials to prosess whole machine or sample test for kinds of climatic factor.Equipment features:Single door(Standard),Optional double-door,Machine dimensions vary with the size of cooling unit.
                  Description

                  Product Description:

                  Name:Walk-in environmental test chamber

                  Type:BND-EK


                  Purpose:

                  Non-standard testing instrument(It is applicatable for the testing of electronics,household appliances, automotive electronics and materials to prosess whole machine or sample test for kinds of climatic factor.


                  Equipment features:

                  Single door(Standard),Optional double-door,Machine dimensions vary with the size of cooling unit.

                  Equipment features:

                  ◆This series product use polyurethane panel,the inner surface is made of stainless steel,the surface of the shell is made of color steel.It has firm structure and easy installing,with a elegant appearance and novel design.

                  ◆We adopt import fittings as our main control fittings to ensure oven quality.

                  ◆Use the newest cooling conrol model in the international , it can adjusted the cooling power of the compressor reach to 0%-100% automatically to realize low energy consumption run of the machine.

                  ◆ Configured with Multi-panel sliding doors and inboard type Illumination,, it provides good observation for the specimen's working.

                  ◆Size and performance can be customized by customers.

                  ◆This system has simple operation and convenient to install,training and Maintenan.


                  Standards Applied:

                  GB2423.1-89 Basic environmental testing procedures for electrician electronic products(Test A Test method of low temperature)

                  GB2423.2-89 Basic environmental testing procedures for electrician electronic products (Test B Test method of high temperature ) GB/T2423.3-93 Basic environmental testing procedures for electrician electronic products (Test method of muggy temperature ) GB/T2423.4-1993 Test Db Test method of alternate muggy temperature

                  GJB150.3-86Test method of military equipment environmental testing (Test of high temperature )

                  GJB150.4-86 Test method of military equipment environmental testing (Test of low temperature )


                  model

                  BND-EK-01Series

                  BND-EK-05Series

                  BND-EK-10Series

                  volume of the workroom(m³)

                  customized according to customers requirements.

                  Specifications

                  temperature range

                  ﹣20ºC ﹣40ºC ﹣60ºC~﹢100ºC

                  humidity range

                  20~98%R.H(﹢20ºC~﹢80ºC)

                  temperature deviation

                  ≤±2ºC

                  humidity deviation

                  ±2.0%RH(>75%RH),±3±2.0%RH(>75%RH),±3.0%RH(≤75%RH)0%RH(≤75%RH)

                  temperature fluctuation

                  ≤±0.5ºC

                  heating rate

                  ≥3-5ºC/min(better than national standard )

                  Cooling rate

                  ≥1-1.5ºC/min(better than national standard )

                  refrigeration compressor

                  Hermetically sealed compressor "Taikang” imported  From French / Semi-hermetic compressor Gulun of German

                  refrigerant

                  environmental protection HFC-R404A/HFC-R23

                  cooling mode

                  Air-Cooling or water-cooling

                  Airflow mode

                  single cycle,stem extension,Stainless Steel centrifuge blade.

                  mode of refrigerant

                  cell refrigeration/double refrigeration

                  Water supply

                  built-in water tank

                  dehumidification

                  freeze

                  control system

                  Fuji of Japan's /a LCD touch screen of Japan's OYO    /LCD touch screen of Korea (TEMI880)

                  Temperature Control

                  procedure&program

                  Security device

                  Multiple alarm device such as:electric leakage,water shortage,overheat,over pressure of compresor,overcurrent

                  Standard Configuration

                  internally heated hollow glass observation window

                  Power Supply

                  380V±10%50Hz 3P+N+G